Combination of fully automatic torque tester and fully automatic sealing angle tester
Online, fully automatic, unmanned
Product portfolio search
Detection object:
Test items:
Testing occasions:
Home / Products List / CanNeed-ATT-Line-2000 Automatic Seal Angle and Torque Tester (Automatic Sampling)

CanNeed-ATT-Line-2000
Automatic Seal Angle and Torque Tester (Automatic Sampling)

Testing occasions:Online/packaging line
Detection object:PET bottled drinks,Cosmetics/drugs/bagged food
Test items:Torque/Torque

Applications

CanNeed-ATT-Line-2000 Automatic Seal Angle and Torque Tester is to test Seal Angle, Opening Torque, Twisting Angle, tightening torque and tightening Angle of bottled drinks. Weighing function is optional.

It can be placed maximum 12 samples, then automatically sampling by conveyor belt. The sample will be measured automatically once arrived at the measurement station and avoid the influence of human factors.

Advantages

1.To test the bottle cap torque value of opening & closing, Seal Angle.

2.Applicable sample size range: All kinds of round bottles which diameter from 55mm-110mm and height ≤360mm.

3. Can be placed maximum 12 samples, then automatically sampling by conveyor belt. The sample will be measured automatically once arrived at the measurement station. Can save 1000 measurements. It can be connected to the production line and can be used alone.

4. Single station. Mechanical structure is more simple and reliable, easy to maintain. With faster speed which can test 6 bottles in 1 min.

5. Stainless steel design / IP 64 protection grade.

6. Sampling method:

1) Place the samples by manual, automatic sampling by conveyor belt and then measure automatically.

2) Can connect to the production line to achieve automatic sampling and automatic measurement.

7. Transfer measurement via RS232 C (standard) interface or via software.

8.For the bottles which diameter smaller than ∅60, can be placed maximum 12 samples. For the NG samples, can be placed 3-6 bottles.

9. Calibration way: Mechanical weight calibration.

Technical Parameter

Measring Range

00.00~10N.m (100Kgf.cm)

Unit

Kgf.cm

Accuracy

±0.5%

Data Line

RS-232 Serial Line, save measurement automatically and transfer to PC

Power

220VAC/50Hz

Air Supply

5~8Bar

Material

Stainless steel mainframe

Applicable sample height range

130~360mm

Applicable bottle cap size range

27.5~50mm

Applicable bottle diameter range

50-125mm

Working temperature

0~45℃

Working humidity

0~85%

Size & Weight

L2200*W900*H2100(Including conveyor line), 300Kg

 

Related Products

页面运行时间: 0.6484375 秒